What does the building code require for attic ventilation, and when does it apply to your house?

Short answer. Georgia's residential code, the 2024 International Residential Code with Georgia amendments effective January 1, 2026, requires vented attics to have net free vent area of 1/150 of the attic floor, or 1/300 when the vents are balanced high and low. It applies to new work under a permit; an older house is generally not forced to upgrade just because the code changed.

How the code reaches your project

Existing houses

Codes generally govern new work. A 1985 house built with gable vents only can usually stay that way until you do work that touches the attic. The moment you replace the roof, though, it is the logical and cheapest time to bring ventilation up to today's standard.

The other rulebook: your shingle warranty

Shingle manufacturers write ventilation requirements into their limited warranties, often referencing the same ratios. A roof installed over a poorly vented attic can face warranty questions later even if no inspector ever looked. That makes the warranty, not the permit, the practical reason most reroofs get a ventilation check.

Who to ask

Your local building department decides which edition and local amendments apply on your permit date, and the Georgia Department of Community Affairs publishes the state amendments. Read roofing permits in Georgia and roofing warranties explained for how the two rulebooks overlap.

In depth

Does a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with workeRidge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust types