What are the attic ventilation code requirements?

Short answer. For homes, attic ventilation rules come from the International Residential Code, which Georgia uses as the base for its residential code: a vented attic needs net free vent area of at least 1/150 of the attic floor area, or 1/300 when 40 to 50 percent of it is exhaust high in the attic. Vents must be screened against weather and pests, and insulation cannot block them.

Here is what a building inspector or plans reviewer is generally looking for. Your local Georgia building department enforces the edition and amendments it has adopted, so confirm details there.

The checklist

The unvented alternative

IRC R806.5 allows an unvented attic if specific conditions are met, typically air impermeable insulation such as spray foam directly against the underside of the roof deck. It is a legitimate design, but it has to be done as a whole system, not by simply closing vents.

Shingle warranties usually expect ventilation that meets code as well. See roofing permits in Georgia and roof ventilation basics.

In depth

Does a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaRidge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with worke