How long should ridge vent nails be?

Short answer. Ridge vent nails must be long enough to pass through the cap shingle and the vent and still penetrate at least 3/4 inch into the wood deck or go fully through it, which is the standard in manufacturer instructions. In practice that usually means nails from about 1 3/4 inches up to 3 inches, depending on how thick the vent and cap shingles are; the vent's instruction sheet lists the minimum.

Do the stack up

Add the thickness of the cap shingle, the vent at the nailing point, and the deck, then make sure the nail reaches 3/4 inch into the deck or pokes through. On a typical 7/16 inch OSB deck, the nail has to go all the way through, since the deck is thinner than 3/4 inch. One manufacturer's spec also accepts about 1/8 inch through rated sheathing.

Nail type

Why it matters

Look up from the attic: properly nailed ridges show nail tips through the deck along both sides of the slot. See wind damage to roofs in Georgia and ridge vent vs box vents.

In depth

Does a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaRidge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with worke