How much venting does an attic need, and do attics need to be vented at all?

Short answer. Most attics need to be vented, and the common rule is about 1 square foot of net free vent area for every 300 square feet of attic floor, half low and half high. Attics designed as sealed, unvented spaces with spray foam on the roof deck are the exception and should not be vented.

Do attics need to be vented?

Quick counts per 1,000 square feet of attic

At the balanced 1/300 ratio, every 1,000 square feet of attic floor needs about 480 square inches of net free area: about 240 intake and 240 exhaust. In practical terms that is roughly:

Scale these for your attic, and check the ratings printed on the products you use.

Placement matters as much as amount

The 1/300 ratio only applies when 40 to 50 percent of the vent area is in the upper part of the attic, within 3 feet of the ridge measured vertically. Exhaust lower on the slope, or gable vents alone, call for the 1/150 ratio. See roof ventilation basics and ridge vent vs box vents.

In depth

Ridge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with workeDoes a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radia