What are the residential attic ventilation requirements?

Short answer. Under Section R806 of the International Residential Code, which Georgia enforces through its state amended edition, an enclosed attic needs cross ventilation with net free vent area of at least 1/150 of the attic floor, or 1/300 when 40 to 50 percent of the vents are high exhaust and the rest are low intake. Vent openings must be screened, and insulation must leave at least a 1 inch air space at the eave vents.

The requirements, section by section

Section numbers below follow recent editions of the International Residential Code.

How it applies in Georgia

Georgia's mandatory residential code is the 2024 International Residential Code with Georgia amendments, effective January 1, 2026. Cities and counties enforce it through permits, and some add local amendments. A reroof permit may not trigger a ventilation review, but shingle warranties still expect code compliant ventilation, so ask your roofer to show the math on the estimate. See roofing permits in Georgia and roofing warranties explained.

In depth

Ridge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesDoes a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with worke