What does Class 3 mean for architectural shingles?

Short answer. A Class 3 rating means the shingle passed the UL 2218 impact test with a 1.75-inch steel ball dropped from 17 feet without cracking through, one step below the top Class 4 rating. Some popular architectural shingles now carry Class 3, which adds hail toughness at little extra cost, but many insurers that offer impact discounts require Class 4.

The UL 2218 ladder

In the UL 2218 test, steel balls are dropped onto the same spot twice, and the shingle passes if the back side shows no crack or rupture.

Which architectural shingles are Class 3

The rating belongs to a specific product and package, not to architectural shingles in general. GAF, for example, says its Timberline HDZ shingles are rated Class 3 when sold in packages that carry the UL 2218 Class 3 statement. Other lines may carry no rating at all. Check the bundle wrapper or the manufacturer's spec sheet rather than a sales brochure.

What Class 3 does and does not do

Class 3 or Class 4?

If an insurance discount is the goal, call your agent before you buy, because many discount programs are written around Class 4. If you simply want a tougher roof at little or no premium, a Class 3 architectural shingle is a sensible middle step. Our guides to impact-resistant shingles in Georgia and Georgia hail season help you judge your risk.

In depth

Are impact-resistant (Class 4) shingles worth it in Georgia?What UL 2218 Class 4 really tests, what it does not promise, how Georgia's FORTIFIED discount law works, and wWhat are the types of roof flashing, and should old flashing be reused?Step, counter, apron, valley and kickout flashing explained for Georgia homes, what the code requires, and whyWhere does ice and water shield go on a Georgia roof?Where self-adhering ice and water membrane belongs on Georgia roofs, what the 2024 IRC ice barrier rule requir

People also ask