Can a range hood vent through a soffit vent?

Short answer. A kitchen range hood should not discharge into a soffit vent or attic; the residential code requires kitchen exhaust to go outdoors, and grease-laden air pulled back into a vented soffit can coat the eaves and attic and create odor and fire concerns. The preferred route is a wall cap or roof cap sized to the hood's duct with a damper, and the code generally requires makeup air for hoods that exhaust more than 400 cubic feet per minute.

Why kitchen exhaust is different

Cooking exhaust carries grease, smoke and steam. A bath fan's moisture is bad enough in an attic, but grease condensing on the soffit, fascia and roof deck is worse. It builds up, collects dust and can feed a fire. Soffit outlets also tend to stain and drip.

Code basics

Best routes

Have an existing soffit outlet?

Look at the soffit near the kitchen for grease stains, drips or a darkened vent, and check the deck near that eave from the attic. Rerouting to a proper cap is usually worth it, and a roof replacement is the easiest time to add one. See roof flashing explained and roof ventilation basics.

In depth

Ridge vent or box vents: which is better, and can you use both?Ridge vents vs box vents, turbines and power fans for Georgia attics: how each works, why mixing exhaust typesDoes a hot Georgia attic shorten the life of your shingles?How hot Georgia attics and shingles get, what research says about ventilation and shingle life, and when radiaHow much attic ventilation does a Georgia roof need?Attic ventilation for Georgia homes: intake and exhaust balance, the IRC R806 1/150 and 1/300 rules with worke